Bio-Chemical Component Analysis
Microvolume Spectrophotometer (미세용량 분광광도계)중앙공동기기센터
장비 한글명 | 미세용량 분광광도계 | Equipment | Microvolume Spectrophotometer |
---|---|---|---|
Model | DS-11+ | Maker | DeNovix |
Purchase Year | 2016 | Location | Room 722 and 725, NIX |
Researcher | Jeong Wan Park | Tel | e-mail: jwpark0801@suwon.ac.kr Tel.: 031-229-8666 |
Fees | Inside University Use: 12,000 won per hour Outside University Use: 6,000 won per sample |
||
Application Field | It is used for the analysis of absorbtion and penetration of light and is also used for the analysis of purity and density of light by optical density of nucleic acid and protein. | ||
Principle and Characteristics | It makes an analysis of optical density of the sample with transition of penetration ray to electric signal by making the light in light source penetrate the sample liquid which is monochromized through Monochormy Spectrophotometer. | ||
Standard Features |
■ Application ■ Nucleic acid, Microarray, Purified Protein & peptide, Absorbance Colorimetrics, ■ Absorbance UV-Vis, OD600 ■ Microvolume mode : sample 1~2㎕ ■ Wavelength Range : 190 – 840 nm ■ Absorbance Range : 0.015-750(1 cm equivalent) ■ Detection limit : 0.04 mg/ml BSA, 0.75ng/㎕ dsDNA ■ Cuvette mode : 10mm, 5mm, 2mm, 1mm pathlength cuvette ■ Absorbance Range : 0.0008-1.5 AU(1 cm) ■ Detection limit : 0.002 mg/ml BSA, 0.04ng/㎕ dsDNA(1 cm) |
HPLC (High Performance Liquid Chromatography, 고성능액체크로마토그래피)중앙공동기기센터
장비 한글명 | 고성능액체크로마토그래피 | Equipment | HPLC (High Performance Liquid Chromatography) |
---|---|---|---|
Model | Waters e2695 | Maker | WATERS |
Purchase Year | 2015 | Location | Room 726, NIX |
Researcher | Jeong Wan Park | Tel | e-mail: jwpark0801@suwon.ac.kr Tel.: 031-229-8666 |
Fees | Inside University Use: 20,000 won per sample/ 10,000 won per standard material Outside University Use: 30,000 won per sample/ 20,000 won per standard material |
||
Application Field | It is used for the analysis of vitamin, sugars, medicines, amino acid and organic acid. | ||
Principle and Characteristics | It measures content by separating organic chemical compounds in the liquid according
to components. It makes the sample penetrate the column by a high-pressure pump and separates components by difference in affinity between bead in the column and the components. It then extracts components through distinct extractors. |
||
Standard Features |
■ Detector : RI, PDA ■ Flow rate range : 0.05 to 5.000 mL/min ■ Max. operating pressure : 5000 psi (0.010 to 3.000 mL/min) ■ Number of sample vials : 120 vials |
UPLC (Ultra Performance Liquid Chromatography, 고성능액체크로마토그래피)중앙공동기기센터
장비 한글명 | 고성능액체크로마토그래피 | Equipment | UPLC (Ultra Performance Liquid Chromatography) |
---|---|---|---|
Model | AcquityH | Maker | WATERS |
Purchase Year | 2015 | Location | Room 726, NIX |
Researcher | Jeong Wan Park | Tel | e-mail : jwpark0801@suwon.ac.kr Tel.: 031-229-8666 |
Fees | Inside University Use: 20,000 won per sample/ 10,000 won per standard material Outside University Use: 30,000 won per sample/ 20,000 won per standard material |
||
Application Field | It is used for the analysis of vitamin, sugars, medicines, amino acid and organic acid. | ||
Principle and Characteristics | It measures content by separating organic chemical compound in the liquid according to
components. It makes the sample penetrate the column by a high-pressure pump and separates components by difference in affinity between bead in the column and the components. It then extracts components through distinct extractors. |
||
Standard Features |
■ Injector : Autosampler ■ Detector : FLR, TUV ■ Pump : Quaternary pump (1 mL/min – 15,000 psi) ■ Column Temp. : 4 – 90 ℃ |
GC (Gas Chromatography, 기체크로마토그래피)중앙공동기기센터
장비 한글명 | 기체크로마토그래피 | Equipment | GC (Gas Chromatography) |
---|---|---|---|
Model | Clarus680 | Maker | PerkinElmer |
Purchase Year | 2015 | Location | Room 726, NIX |
Researcher | Jeong Wan Park | Tel | e-mail : jwpark0801@suwon.ac.kr Tel.: 031-229-8666 |
Fees | Inside University Use: 20,000 won per sample/ 10,000 won per standard material Outside University Use: 40,000 won per sample/ 20,000 won per standard material |
||
Application Field | It is used for the quantitative and qualitative analysis of fatty acid, and volatile compounds. | ||
Principle and Characteristics | It uses gas as mobile bed and makes the sample penetrate the column by evaporating the sample with heat right after injection. It then extracts components through distinct extractors. | ||
Standard Features |
■ Injector : Autosampler ■ Detector : FID ■ Number of sample vials : 108 vials |